ALARMS Always firing, never read.
A badly set threshold alerts a hundred times. One that does not know the data stopped arriving never alerts at all.
Alarms, included in the Lynx core, monitors any measurement in the plant and alerts you by email, Teams, Telegram, WhatsApp or SMS when it goes out of limits. And it diagnoses the events the devices themselves report.
- 24Monitored
- 2In alarm
- 1No data
- 1Needs review
- 3Paused
| Status | Name | Asset and measurement | Condition | Last value | Recipients |
|---|---|---|---|---|---|
| In alarm | Transformer 2 temperature > 85 °C | Winding temperaturePlant 1 › Substation › Transformer 2 | > 85 °C | 87.4 °C2 min ago | Electrical maintenance |
| In alarm | Low compressed air pressure | Outlet pressurePlant 1 › Compressors › C-1 | < 6.5 bar | 6.1 bar9 min ago | Only me |
| No data | Line 3 consumption | Active powerPlant 2 › Line 3 | > 520 kW | —1 h 12 min ago | Shift operations |
| Normal | Main switchboard temperature | Internal temperaturePlant 1 › Substation › MSB | > 45 °C | 31.8 °C1 min ago | Electrical maintenance |
| Needs review | Overall power factor | Power factorPlant 1 › Substation › Incomer | < 0.92 | —measurement removed | Only me |
| Paused | Exhaust fan E-4 vibration | RMS vibrationPlant 2 › Exhaust › E-4 | > 7.1 mm/s | 4.2 mm/s2 days ago | Only me |
Product screens with sample data: no figure on these screens comes from a plant.
FROM ANY CHART Tested before you save it
You create it from a chart, with the asset and the measurement already set. The form tells you how many times it would have fired in the last 7 days.
- 1What to monitorDevicePlant 1 › Substation › Transformer 2Data typeWinding temperature (°C)From the chart “Winding temperature · Transformer 2” · instantaneous data type
- 2Evaluation periodEach valueAverage over a periodOn counters, such as energy consumed, the period is mandatory and the consumption over the window is evaluated.
- 3When to alertAboveBelowOut of rangeMaximum value85 °CWith this condition, the alarm would have fired 2 times in the last 7 days
- 4Who to alertOnly meElectrical maintenance
- 5How to alertEmailTeamsTelegramWhatsAppmonthly quotaSMSmonthly quota
- Any measurement
Measured on a device or calculated by the platform: monitored the same way.
- Three conditions
Above, below or out of range, on each value or on the average of a period.
- Counters by consumption
It compares what was consumed in the window —120 kWh in the last hour—, not the reading.
FOUR STATES Out of limits, or no data
“No data” recovers on its own when communication returns. “Needs review” needs someone: the measurement no longer exists.
- Alarm periods in plain sightThreshold drawn and every out-of-limits period shaded.
- Event timelineEvery change of state, with who was alerted and on which channel.
- A faithful historyIt keeps the thresholds of each moment and does not fill the gaps.
- In alarm
- Normal
- No data
- Needs review
- Asset and measurement
- Transformer 2 · Winding temperature
- Condition
- Above 85 °C
- Last value
- 87.4 °C · 10:42
- Channels
- Email, Teams, WhatsApp
- In alarm87.4 °C · exceeds the maximumEmail, Teams, WhatsApp
- Normal83.2 °C · back below the maximumEmail, Teams
- In alarm88.6 °C · exceeds the maximumEmail, Teams, WhatsApp
- NormalData received againEmail
- No dataNo data received from the meterEmail
FIVE CHANNELS When it fires and when it clears
In your language and time zone, and at most one alert every 15 minutes. If the monthly WhatsApp and SMS quota runs out, the alert goes by email.
- EmailFull detail
- Microsoft TeamsTeam channel
- TelegramShift groups
- WhatsAppTechnician’s phone
- SMSNo data coverage


AND WHAT THE DEVICES REPORT What each stoppage took down with it
Lynx groups each asset’s alarm intervals into state periods, with the manufacturer’s code and criticality, and estimates their impact: in photovoltaics, the energy lost.
- Card per siteName, availability percentage and the set of associated assets.
- Events per assetEach asset shows its number of alarm-type events and a 0–100 availability bar.
- Estimated impactIn photovoltaic, lost energy computed from the inverter's nominal power and the radiation during the alarm state.
- OK
- INFO
- WARNING
- MINOR
- MAJOR
- OTHER
MINOR and MAJOR are the critical levels, with real impact.

From the alarm to the diagnosis
We prepare a demo with the measurements of one of your sites and the thresholds you would set.
Or write to us directly at sales@lynxplatform.net